HOME  PRODUCTS  BURN OFF OVENS MODEL 3375-RT

TESTIMONIALS

THE ORIGINAL BURN OFF OVENS
Read More

Burn Off Ovens - Model 3375-RT

The 3375-RT is a micro-ramp control heat cleaning oven. The system consists of a programmed digital microprocessor-based time-temperature controller as well as a system that suppresses the water flow. This system is used to support high combustible loads by suppressing the combustion.

 
ACE MICRO-RAMP HEAT CLEANING OVEN FEATURES
PHYSICAL
Sr. No. Component Specifications
1 Inside Dimensions W/O Cart 60″ W × 180″ D × 72″ H
2 Inside Dimensions With Cart 60″ W × 180″ D × 60″ H
3 Volume Over Cart 375 CU. FT.
4 Single Platform Cart Dimensions 57″ W × 177″ D × 12″ H
5 Outside Dimensions 108″ W × 212″ D × 85″ H
6 Shipping Weight 7,500 LBS.
7 Location of Controls Right Side
8 Location of Exhaust Stack Top Rear Left Corner
9 Exhaust Stack I.D. 16″
10 Exhaust Stack O.D. 20″

 

CONSTRUCTION (8,000 LBS.)
Sr. No. Component Specifications
1 Cart Rating 7.25 LBS/FT
2 Cart 4″ Structural Channel 11 Ga. CRS
3 Oven Steel Enclosure 1/4″ CRS Plate
4 Oven Enclosure Front Face Standard
5 Angle Iron Reinforced Enclosure Standard
6 Blanket Insulation 4″ Thick 2,300°F. Standard
7 Aluminized Coating Inside Enclosure 3/16″ CRS
8 Steel Floor Covers Over 4″ Insulation Blue Enamel
9 * Exterior Finish Hi-Temp. 2,300°F. 2″ Thick
10 Exhaust Stack Insulation Rated 30.01 SQ. FT.
11 2 Top Mounted Pressure Relief Hatch 1:15.00 Vent Ratio
12 Oven Volume 450.00 CU. FT. 6
13 Qty Primary Water Nozzles Installed 8
14 Qty Secondary Water Nozzles Installed 2
15 Qty Primary Burners 1
16 Qty Afterburners  
17 * NFPA Preferred Vent Ratio: 1:15 
1 SQ. FT. of relief panel for every15 CU. FT. of oven volume.

 

CONTROLS
Sr. No. Component Specifications
1 Primary Burner - Normal 900°F (482°C)
2 Afterburner - Normal 1,600°F (871°C)
3 Over Temp. Control Standard
4 Primary Water Spray Standard
5 Secondary Water Spray Optional OA-1080
6 NFPA-86A Specifications Optional
7 FM Specifications Optional OA-2600
8 U.L. Listed Control Panel Standard
9 ISO Control Certified Standard
10 Primary Burner off on Loss of A.B. Standard
11 Primary Burners Rated For 800,000 BTU/HR
12 Smart ASS, Automatic Shutoff System Optional OA-1090
13 One Touch Control (OTC) Optional
14 High Fire Afterburner 1,500°F (798°C) Optional

 

Cycle Time/Capacity
Component Specifications
* Normal Cycle Time 2 to 8 Hours
* Combustible Capacity 70 LBS/HR

 

Fuel Electric Water
Sr. No. Component Specifications Component Specifications Component Specifications
1 Primary Burner Input Burner 1 150,000 BTU/HR Voltage/Phase/
Hertz
120/1/60 Normal Less Than 3.6 Gal/HR.
2 Primary Burner Input Burner 2 175,000 BTU/HR Amps * 5 to 10 Capacity 6 Gal./HR. Ea. Nozzle
3 Afterburner Input 600,000 BTU/HR     Min/Ma× Pressure 30 to 60 PSI
4 Natural Gas Inlet Pressure 8″ to 14″ W.C.        
5 Propane Inlet Gas Pressure 12″ to 18″ W.C.        
6 Gas Inlet Pipe Size 1-1/2″        

 

At ACE, it is our constant endeavor to provide our clients with the best products using the latest technologies. Our products are aimed at improving processes, leading to higher levels of efficiency.